top of page

FILTERATION SYSTEM

Vacuum Filtration

Vacuum filtration

Glass Filter Holders

image.png

Borosilicate Glass

25 / 47 / 90 mm filters

Borosilicate-glass filtration assemblies for routine laboratory liquid filtration.

  • Sintered-glass support screen

  • Silicone rubber stopper

  • Anodized aluminium clamp

  • Funnel capacities: 300, 500 and 1,000 ml

Models: GFH300 · GFH500 · GFH1000

Vacuum filtration

Stainless-Steel Filter Holders

image.png

SS316 - 47 mm filter

Robust holder assemblies for laboratory filtration applications requiring metal construction.

  • SS316 support screen and integrated clamp

  • Silicone rubber stopper

  • Funnel capacities: 300, 500 and 1,000 ml

  • Separate duck-clamp configurations available

Models: SFH300 · SFH500 · SFH1000 · FHDC series

Vacuum filtration

Magnetic Filter Holders

image.png

Polysulfide
PES support

Magnetic-clamp filter holders designed for convenient assembly and sample filtration.

  • Magnetic clamp and silicone stopper
    47 mm filter size

  • Funnel capacities: 300 and 500 ml

Models: MAG300 · MAG500

Vacuum filtration

PSU & Spin-Lock Filter Holders

image.png

47 mm filter

Specialized holder configurations with spin-lock or related fastening arrangements.

  • Polysulfide body and PES support screen listed for PSU holder

  • Silicone rubber stopper

  • PSU funnel capacity: 300 ml

  • Spin-lock SS316 holders listed in 300 and 500 ml

Models: PSU300 · SPFH300 · SPFH500

Manifolds

Vacuum Filtration Manifolds

image.png
image.png

1 / 3 / 6 stages

Multi-position systems to run multiple filtration processes in parallel.

  • SS316 Microfilt 47 options

  • PTFE two-way valves on selected configurations

  • Mirror polish listed for SS316 manifolds

  • 1/2-inch hose connection (12 mm) listed

  • Silicone stopper; autoclave information listed at 120°C for 10 minutes for selected models

Models: PSU300 · SPFH300 · SPFH500

Vacuum filtration

Disposable M-Funnels

image.png

Polypropylene
Gamma-sterilization packing listed

​Disposable polypropylene funnels for compatible filtration assemblies.

  • 47 mm filter size

  • Funnel capacities: 100 and 250 ml

  • Compatible configurations depend on holder system

Models: DMF100 · DMF250

Vacuum filtration

Hydrofil Filter Holders

image.png

SS316
Spin-lock

SS316 filter-holder configuration for liquid filtration workflows.

  • SS316 support screen

  • Silicone rubber stopper

  • 47 mm filter size

  • Catalogue lists 500 ml and 1,300 ml capacity variants; confirm exact model

Models listed: HFH300 · HFH500 (verify capacity/model match)

Manifolds

GMP & Clamp-Style Manifolds

image.png

GMP configuration

Alternative manifold styles with selectable stages and holder-clamp arrangements.

  • 1-stage, 3-stage and 6-stage options listed for GMP family

  • Inbuilt-clamp and duck-clamp 3- and 6-stage variants

  • Confirm exact valve, connection and holder configuration before selection

Models: GMP01 / GMP03 / GMP06 · VFCIC · VFCDC

Complete kits

Vacuum Filtration Manifold Kits

image.png

3-stage / 6-stage

Configured filtration kits combining the manifold and essential accessories.

  • SS316 filter funnel, 300 ml

  • 2 L vacuum flask

  • AE45S pump listed for 3-stage kit; AE75S for 6-stage kit

  • PTFE air-vent filter, 50 mm / 0.2 µm

  • 47 mm × 0.45 µm cellulose nitrate membrane filters

  • Vacuum trap, silicone tubing and forceps

Models: MF47C-03 · MF47C-06

Compact filtration

Micro Vacc Compact Systems

image.png

1 / 3 branches

Compact vacuum systems with multiple connection and holder options.

  • Maximum vacuum listed: 313 mbar

  • Maximum liquid flow rate listed: 0.5 L/min

  • 12 W brushless DC motor

  • 8 mm hose barb; approximate dimensions 7 × 6 × 6 inches

  • Holder options include Microfilt funnel, PSU, SS and spin-lock styles

Models: MV1-C1 / C2 / C3 / C4 · MV3-C1 / C2 / C3 / C4

Solvent filtration

Solvent Filtration Assemblies

image.png

Glass or SS holder

Complete assemblies for laboratory solvent filtration with selectable holder type.

  • SS holder, duck-clamp or glass-holder assembly

  • Selected configuration includes 1 L glass flask

  • 15 LPM oil-free vacuum pump listed

  • 47 mm × 0.45 µm cellulose nitrate membrane filter and SS forceps listed

  • Silicone tubing included in the described assembly

Models: SFCA-IC · SFCA-DC · SFCA-GF

Pressure filtration

Syringe Filter Holders

image.png

SS316
10 / 22 mm filters

Stainless-steel syringe holders with Luer fittings for sample filtration.

  • PTFE gasket listed

  • Female Luer-lock inlet and male Luer-slip outlet

  • Filtration areas listed: 0.9 cm² and 3.8 cm²

  • Inlet pressure listed: 7 kg/cm²

Models: SF13 · SF25

Pressure filtration

Inline Stainless-Steel Holders

image.png

SS316
25 / 47 mm filters

Inline holders for liquid and gas applications, including point-of-use filtration.

  • Non-threaded sanitary inlet/outlet connections on described models

  • Silicone gasket / O-ring

  • 3/8-inch hose connection listed

  • Filtration areas: 3.7 cm² and 12.5 cm²

  • Pressure values vary by model; confirm before use

Models: IFH25 · IFH47

Pressure filtration

Membrane Filter Holders

image.png

SS316

Pressure holders for inline gas or liquid filtration, ultracleaning and selected pilot tests.

  • Model sizes: 90, 142 and 293 mm membrane filters

  • Pre-filter sizes listed: 76, 124 and 257 mm

  • Filtration areas listed: 55, 127 and 518 cm²

  • Silicone O-ring listed

  • Connections and pressure ratings vary by configuration

Models: MFH-90 · MFH-142 · MFH-293

Process filtration

Capsule Filtration Systems

image.png

SS316L pressure vessel

Pressure-vessel systems intended for capsule filtration of high-purity solvents.

  • For analytical and pharmaceutical process-development workflows

  • Extended outlet designed for direct capsule-filter fitment

  • Designed to reduce reliance on elastomeric seals at the capsule interface

  • Confirm capsule compatibility and operating limits for the chosen setup

System configuration depends on application

Vacuum pumps

Oil-Free Vacuum Pumps

image.png

Multiple flow options

Oil-free pumps for laboratory filtration and related vacuum or pressure applications.

  • Catalogue models include AE15, AE25S, AE45, AE75, AE45S, AE75S and CRP variants

  • Listed flow rates span approximately 15–75 LPM across different models

  • Vacuum, pressure, stage, hose connection, weight and motor ratings vary by model

  • Check the exact model specification before choosing a pump

AE series · Chemical-resistant application variants listed

Water testing

Silt Density Index (SDI) Test Kit

image.png

SS316 holder
47 mm filter

Manual test kit for field assessment of feed-water conditions in reverse-osmosis systems.

  • Pressure gauge and regulator

  • Stainless-steel on/off valve and 1.5-inch TC clamp

  • 8 × 6 mm PU tube

  • 47 mm × 0.45 µm membrane filters; pack of 100 listed

  • 500 ml measuring beaker, blunt SS forceps, stopwatch and PVC read-bore component

Models: MFH-90 · MFH-142 · MFH-293

Contamination analysis

Fluid Contamination Analysis Kit

image.png

Sample analysis setup

Equipment set for fluid contamination analysis and patch testing.

  • 47 mm filter holder and flask

  • Vacuum pump listed at 45 LPM

  • 5 L dispensing pressure vessel with pressure jet gun

  • Digital analytical balance listed at 0.1 mg

  • Laboratory hot-air oven, membrane filters, 1 L vacuum flask and tubing

  • SS tray, Petri dish, measuring jug, 150 mm desiccator and forceps

Configuration and included accessories should be confirmed

Contamination analysis

Contamination Patch Test Kit

image.png

Multiple flow options

Filtration and sample-handling components for contamination patch test workflows.

  • Glass filtration assembly with flask; 25 or 47 mm options listed

  • Membrane filters listed at 0.8 µm

  • 15 LPM vacuum pump with tubing

  • 500 ml measuring beaker and wash bottle

  • 300 ml sample bottle and SS forceps

Select filter diameter and quantity for the required workflow

Pressure equipment

Dispensing Pressure Vessels

image.png

5 / 10 / 20 L options

Pressure vessels listed for laboratory dispensing and compatible filtration setups.

  • Pressure gauge with vent valve

  • Oil-free vacuum pump and PU tubing listed in a described setup

  • Capsule filter option listed: PES, 0.45 × 2 format

  • Confirm vessel ratings, fittings and compatibility before operation

Capacity options: 5 L · 10 L · 20 L

Sample preparation

Solid Phase Extraction (SPE) Manifolds

image.png

12-port / 24-port

Manifold systems for multi-sample solid phase extraction and analytical sample preparation.

  • Acrylic chamber and collection rack

  • Acrylic waste container and Teflon lid

  • One-way stopcocks and port-size gaskets

  • Vacuum gauge, regulator, tubing and ejector tool

  • Glass test tubes listed at 18 × 150 mm

Models: SPE12 · SPE24

SPE accessories

SPE Accessories & Consumables

image.png

Components to configure and maintain solid phase extraction workflows.

  • Stopcocks and bottle caps

  • Vacuum gauges and regulator sets

  • Vacuum traps and silicone tubing

  • SPE cartridges

  • Collection racks, waste containers and related parts

Choose accessories compatible with the selected manifold

IR / FTIR accessories

Circular Pellet Die Sets

image.png

SS / HSS construction listed

Precision die sets used to prepare round pellets for IR and FTIR analysis.

  • Hardened HSS M2 die plunger

  • Aluminium anvil listed

  • Diameter options: 3, 5, 8, 10, 12, 13, 15, 20, 25, 30, 40 and 50 mm

  • Maximum loads vary by diameter: 5T, 10T, 25T or 40T as listed

Select die diameter and rated load for the application

IR / FTIR accessories

KBr Presses — Manual & Automatic

image.png

15T / 30T models listed

Press systems for forming potassium bromide pellets for IR and FTIR spectroscopy.

  • Maximum working pressure listed: 135 kg/cm²

  • 230 V AC mains supply listed for automatic press

  • Piston diameter, stroke, table size and workspace vary by model

  • Catalogue lists manual and automatic configurations

Confirm model, force rating, workspace and dimensions

HPLC consumables

Sample Filtration Kits

image.png

Sample-filtration accessories for chromatography and analytical sample preparation.

  • 10 ml gas-tight glass syringe with male Luer connection

  • SS316L syringe filter holder

  • 13 mm and 25 mm holder/filter options listed

  • 0.45 µm membrane filter; Nylon 66, 47 mm, pack of 100 listed

  • Needle set

Select membrane material and holder format for compatibility

Membrane filters

Membrane Filter Papers

image.png

0.05–10 µm listed

Membranes for sample separation, purification, filtration and laboratory analytical workflows.

  • Materials listed: PES, MCE, Nylon, PVDF and hydrophobic PTFE

  • Diameters listed: 13, 25, 37, 47, 90, 142 and 293 mm

  • PES: hydrophilic, low protein binding as described

  • MCE: high porosity and biological inertness as described

  • Nylon, PVDF and PTFE options offer different compatibility characteristics

Confirm membrane material, diameter and pore size for each method

HPLC storage

HPLC Column Storage Cabinets

image.png

60 / 120 column capacity

Storage cabinets designed to organize and protect laboratory chromatography columns.

  • 60-column cabinet listed with six drawers

  • 120-column cabinet listed with six or other drawer arrangements in catalogue

  • Example dimensions listed: 280 × 1,210 × 410 mm

  • Lock and key option listed

  • ABS, MS or SS construction options referenced

Models: CSC-6P · CSC-12P

Disposable filters

Disposable Syringe Filters

image.png

13 / 25 mm
0.22 / 0.45 µm listed

Disposable membrane filters in multiple materials for sample preparation and liquid filtration.

  • Nylon: hydrophilic, suitable for a range of aqueous and chemical solutions

  • PES: high flow and low protein binding as described in the catalogue

  • PVDF: chemical stability and heat-resistance characteristics depend on type

  • PTFE: broad solvent compatibility; hydrophilic and hydrophobic types are listed

Material selection depends on sample chemistry and method

Vacuum equipment

Degassing Chambers

image.png

SS304 models

Vacuum chambers with stainless-steel chamber body and transparent acrylic lid.

  • Capacities: 5, 10, 20 and 50 L

  • Silicone vacuum gasket and gauge assembly

  • Air-tight brass valve assembly with vent-port filter described

  • Silicone vacuum hose listed at 1 m length, 8 mm ID and 14 mm OD

  • Catalogue describes 4 mm chamber thickness for listed models

Models: AVC05 · AVC10 · AVC20 · AVC50

Gas sampling

Gas Sampling Cylinders

image.png

Multiple capacity options

Stainless-steel cylinders for gas sample storage and transport.

  • Common capacities listed: 250, 300, 500, 1,000, 2,000, 2,500, 4,000 and 5,000 ml

  • Catalogue table lists 5,000 PSIG pressure rating for certain models

  • Connection type, dimensions and construction vary by model

  • Confirm pressure rating, valve arrangement and service suitability before use

AE sampling-cylinder series

Liquid sampling

Liquid Sampling Bombs

image.png

SS304 / SS316

Stainless-steel sampling vessels for liquid, oil or compatible sample handling.

  • Single-ended and double-ended types listed

  • Internal volume listed: 40–3,800 ml

  • Wall thickness listed: 2–5 mm

  • Working pressure must be confirmed against the selected vessel documentation

Choose material, capacity, end type and rated conditions

bottom of page